Home
Represented Companies Print

We are proud to represent the following companies:


Supreme Heat:  waste oil furnaces               MCS:  portable diesel-fired radiant heaters

QuietCool:  portable evaporative coolers      Alternate Heating Systems:  waste oil and wood boilers

Hago:  nozzles                                               Crown:  electrodes 

Carlin:  controllers, transformers                   Suntec:  pumps

Norgren:  oil and air regulators                      R.W. Beckett:  burners, motors, blower wheels

Metal Fab:  class A chimney                          Webster:  transformers

Lenz:  gauges, filter assemblies                     Combu:  filter assemblies, solenoids, check valves, ball valves

Delavan:  nozzles, flame cones                     White Rogers:  controllers, thermostats, fan limit switches

Premium 5144 Filters                                    Honeywell:  controllers, cad cells, fan limit switches, thermostats

PLEASE ARROW DOWN FOR MORE INFORMATION

SUPREME HEAT WASTE OIL FURNACES

Supreme on WBT

Model

Maximum Firing Capacity

Dimensions

Supreme 1750

1.25 gallons/hr

98"L x 21"T x 21"W

Supreme 2750

1.9 gallons/hr

105"L x 24"T x 24"W

Supreme 4250

3.0 gallons/hr 130"L x 32"T x 32"W
UL listed tank and stand optional  

SUPREME FURNACE FEATURES & BENEFITS

1.   Single pass heat exchanger -easier to clean (15-20 min.) - saves service costs

2.   Full width door in exchanger - can inspect the whole exchanger - easier to remove ash

3.   Every inch of exchanger air scrubbed - protects against burn outs - removes more heat

4.   Five times as much exchange area - more efficient than some competitors units.

      - protects against burn outs

5.   Comes standard with two unique nozzle - Saves down time (10 min. to change out lines)

      - Saves travel and service charges - Rarely needs flushing

      - Brings more dependability and confidence - components most likely to fail in one unit

6.   Door can be hinged either side. - better choice of installation - better access for service

7.   Flue outlet either side - better choices for installation - easier to meet code clearances

8.   On board air compressor - can turn off shop air at night - eliminates starting large motor for air

      - eliminates hose breaking and burning up compressor at night

9.   Shop air also UL approved - more quiet - can utilize shop air if on anyway

10. Fan is covered - has the appearance of a finished product - looks like your money bought something

11. UL approved - assures your insurance company - meets fire and building codes

12. Metering pump system - can burn full approved viscosity range without adjustment of fuel

13. Most user friendly - easy to maintain yourself - Simple in design and function

14. No burn out target - less expensive to maintain

15. Dormant off cycle - $20--$40.00 savings per month - Heaters auto-off in summer

Portable Radiant Diesel Heaters

XL9SR

 HEAT OUTPUT LOW/HIGHPOWER SUPPLYFUEL CONSUMPTION

EMPTY  WEIGHT

DIMENSIONS
(LxWxH)
TANK SIZEHEAT TYPE 

MCS

Low:100,000BTU

High:147,000BTU

115Volts 1.3Amps.75 Gallons of Diesel Per Hour on Low152 lbs47.25”x30”x44.5”15.8GallonRadiant

KARCHER

Sweepers/Scrubbers/Extractors/

Floor Machines/Vacuums

70/3040/15 ScrubberPuzzi 8/151/175/300 Floor Machine

75/4090/60 Ride On


PT Literature

WOOD GASIFICATION BOILERS

Airflow Diagram

Multiple Sizes of Wood Gasification Boilers

Model:

E100

E140

E180

E200

E250

BTU/H (Max.) Wood

100,000

140,000

150,000

185,000

230,000

Oil (optional) **

80,000

130,000

160,000

160,000

230,000

Heating Surface

30 ft2

39 ft2

46 ft2

55 ft2

70 ft2

Water Capacity

60 Gal

80 Gal

80 Gal

95 Gal

140 Gal

Fire Box Capacity

6.5 ft3

10 ft3.

14 ft3

18 ft3

22 ft3

Max. Log Length

26"

30"

30"

38"

46"

Door Opening

14" x14"

14" x14"

14" x14"

14" x14"

14" x14"

Height

58"

64"

66"

66"

74"

Width

26"

26"

31"

31"

31"

Depth

44"

48"

48"

56"

66"

Flue Size

6"

6"

6"

8"

8"

Weight (lbs)

1,400

1,650

2,100

2,400

3,000

Domestic Coil Gal/min (Optional)

5

5

5

5

5

Rec. Sizing: for 8 - 12 hour burn cycle (BTU/hr)

70,000

100,000

140,000

175,000

220,000

Model:

E500

E1000

BTU/H (Max.) Wood

500,000

1,000,000

Net Steam Rating (BTU/H)

376,000

752,000

Heating Surface

116 ft2

192 ft2

Water Capacity

210 Gal

435 Gal

Gas/Oil Chamber (water capacity)

16 Gal

50 Gal

Height

90"

102"

Width

34"

48"

Depth

72"

78"

Flue Size

8"

12"

Weight (w/o gas/oil - lbs)

4,500

9000

ID Fan

.75 HP

2.0 HP

Minimum Boiler Room (w/o Gas/Oil)

12'x15'

16'x16'

Minimum Boiler Room (with Gas/Oil)

14'x15'

16'x18'

Load Door

18"x18"

18"x18"

* Specifications and design subject to change without notice.
All specifications shown are approximate.


The Alternate Heating Systems Water Wall

Each Alternate Heating Systems boiler, heater and furnace is designed so that every piece of steel is in contact with the water in the system that is used to transfer heat to your radiant floor heat system, radiator, baseboard hot water, or heat exchanger.  This design ensures the most rapid and efficient heat transfer from the firebox into the water.  Efficiency is increased compared to other boilers that do not have this feature by allowing less heat to escape from the boiler surfaces before it is captured in the water.

ASME Certification

The American Society of Mechanical Engineers certification is available on any of our boiler lines for an additional charge.  This certification assures that the pressure vessel has been designed and constructed in accordance with the ASME Code.  This certification is required for all commercial installations.  The certification is also required for some residential installations depending upon local codes - it is up to the homeowner to determine the need for an ASME certification on any boiler purchased.

10 Year Limited Warranty

 
© 2018 Waste Oil Furnace Distributing, LLC