We are proud to represent the following companies:


Supreme Heat:  waste oil furnaces              Val6:  portable diesel-fired radiant heaters

QuietCool:  portable evaporative coolers      Alternate Heating Systems:  waste oil and wood boilers

Hago:  nozzles                                                Crown:  electrodes 

Carlin:  controllers, transformers                   Suntec:  pumps

Norgren:  oil and air regulators                      R.W. Beckett:  burners, motors, blower wheels

Metal Fab:  class A chimney                          Webster:  transformers

Lenz:  gauges, filter assemblies                     Combu:  filter assemblies, solenoids, check valves, ball valves

Delavan:  nozzles, flame cones                      White Rogers:  controllers, thermostats, fan limit switches

Honeywell:  controllers, cad cells, fan limit switches, thermostats

Supreme on WBT

SUPREME HEAT WASTE OIL FURNACES

Model

Maximum Firing Capacity

Dimensions

Supreme 1750

1.25 gallons/hr

98"L x 21"T x 21"W

Supreme 2750

1.9 gallons/hr

105"L x 24"T x 24" W

UL listed tank and stand optional

  
   

SUPREME FURNACE FEATURES & BENEFITS

1.   Single pass heat exchanger -easier to clean (15-20 min.) - saves service costs

2.   Full width door in exchanger - can inspect the whole exchanger - easier to remove ash

3.   Every inch of exchanger air scrubbed - protects against burn outs - removes more heat

4.   Five times as much exchange area - more efficient than some competitors units.

      - protects against burn outs

5.   Comes standard with two unique nozzle - Saves down time (10 min. to change out lines)

      - Saves travel and service charges - Rarely needs flushing

      - Brings more dependability and confidence - components most likely to fail in one unit

6.   Door can be hinged either side. - better choice of installation - better access for service

7.   Flue outlet either side - better choices for installation - easier to meet code clearances

8.   On board air compressor - can turn off shop air at night - eliminates starting large motor for air

      - eliminates hose breaking and burning up compressor at night

9.   Shop air also UL approved - more quiet - can utilize shop air if on anyway

10. Fan is covered - has the appearance of a finished product - looks like your money bought something

11. UL approved - assures your insurance company - meets fire and building codes

12. Metering pump system - can burn full approved viscosity range without adjustment of fuel

13. Most user friendly - easy to maintain yourself - Simple in design and function

14. No burn out target - less expensive to maintain

15. Dormant off cycle - $20--$40.00 savings per month - Heaters auto-off in summer

  val 6

PORTABLE

VAL6 Infrared Heaters

Model

KBE5S

KBE5L

EPX

DAYSTAR

HOTGUN

Heat Output

111,000 BTU/hr

111,000 BTU/hr

100,000 BTU/hr on low; 140,000 BTU/hr on high

51,800 BTU/hr

116,000 BTU/hr

Fuel

Consumption

0.85 gal/hr

0.85 gal/hr

0.75 gal/hr on low; 1.02 gal/hr on high

0.4 gal/hr

0.9 gal/hr

Fuel

Diesel, Kerosene

Diesel, Kerosene

Diesel, Kerosene

Diesel, Kerosene

Diesel, Kerosene

Tank

Capacity

9 gallons

15.1 gallons

15.4 gallons

2.6 gallons

14.3 gallons

Power

Source

120V 60Hz, single phase

120V 60Hz, single phase

120V 60Hz, single phase

120V 60Hz, single phase

120V 60Hz, single phase

Power

Consumption

100W

100W

96W on low; 97W on high; 123W on ignition 

120W

176W

Safety

Device

Photocell flame monitor, 3A fuse; Tip-over switch

Photocell flame monitor, 3A fuse; Tip-over switch

Photocell flame monitor, 3A fuse; Overheat protection; Tip-over switch

Photocell flame monitor, 3A fuse; Overheat prevention system; Tip-over switch

Photocell flame monitor, 3A fuse; Overheat prevention system; Tip-over switch

Burner Type

High pressure spray gun

High pressure spray gun

High pressure spray gun

High pressure spray gun

High pressure spray gun

Control

System

5 sec. Prepurge, 180 sec. Postpurge

5 sec. Prepurge, 180 sec. Postpurge

5 sec. Prepurge, 180 sec. Postpurge

5 sec. Prepurge, 180 sec. Postpurge

5 sec. Prepurge, 180 sec. Postpurge

External

Dimensions

(H x W x L)

36.4 x 27.9 x 27.4 (in.)

37.5 x 28.0 x 29.2 (in.)

38.2 x 25.4 x 48.6 (in.)

23.4 x 12.2 x 22.8 (in.)

30.8 x 22.3 x 28.1 (in.)

Features

  

Built-in thermostat, High/low switch

  

Dry Weight

83.8 lbs

92.6 lbs

110 lbs

40 lbs

82 lbs

GREAT ADVANTAGES WITH VAL6:

Sunlight Warmth

VAL6’s radiant heat penetrates

  evenly on and into surfaces just

 like sunlight and can be connected

to a room thermostat.

Best Choice for Outdoors

VAL6’s performance is unique in the

 outdoors and unlike forced air

heaters, which loose heat from wind

 and cold air and can be run on a 12

volt adapter

No Air Movement Dust Free

VAl6 generates straightforward

infrared heat which is unaffected

by air flow, thus creating a

comfortable and dust-free

environment and it's low noise.

Odorless

VAL6’s perfect combustion system

produces no odor and no smoke

while running. The exhaust gas

goes upward.  99% Efficient 

 

 

Quiet Cool Evaporative

Coolers

For Many Industrial Applications

 QC36D1
36" Direct drive, Single speed, 1/2 HP. Rated @ 9700 cfm.
QuietCool's most economical model.

QC36B1 36" Belt drive, Single speed, 1/2 HP.
QC36B3
36" Belt drive, Three speed, 1/2 HP. QC36B1X 36" Belt drive, Single speed, 3/4 HP.
- 1/2 HP models rated @ 9700 cfm.
- 3/4 HP model rated @ 10,900 cfm.
QuietCool belt drive models are the Standard for quiet.

 QC36B1XHL
36" Belt drive, Single speed, 3/4 HP, Hazardous locations. Rated @ 10,900 cfm. Class I, Group D. Class II, Groups F & G.

Benefits and Features

  1. Maintenance Free - Designed and manufactured to he virtually maintenance free.
  2. Easy to operate - Needs only water and electricity to operate.
  3. No waste - Highly efficient system, no water is wasted.
  4. Easy to move - Completely portable, so anyone can roll it quickly to any hot area.
  5. Amazingly Cooler air - Discharged air is up to 20°F degrees cooler than the incoming air.
  6. Filtered Air - Filters the air as is passes through the cooling media eliminating many air born particles.
  7. Plus - Portable 60 gallon water reservoir is available where no water supply is readily accessible.

Note: The QuietCool Portable Evaporative Cooler has ETL Approval #9800103 which conforms to UL standard 507.

Construction

  1. Housing - Constructed of rotomolded, corrosion free polyethelyne.
  2. Fan - Industrial duty galvanized steel construction.
  3. Fan Motor - High efficiency for a long life.
  4. Recirculating Pump - High efficiency, maintenance free. and corrosion resistant submersible pump.
  5. Float Valve - Corrosion and maintenance free plastic.
  6. Water Lines/Fittings - All corrosion free materials.
  7. Cooling Media - Cross corrugated angle fluted specially formulated cellulose material treated with a thermosetting resin. Specially designed for evaporative cooling so there is no excess load on the fan.

 

WASTE OIL BOILERS

  Turn a Liability into an Asset
 

 

Waste Oil Heater/Boiler - B Series

 

 

 THE ULTIMATE ANSWER TO USED OIL DISPOSAL PROBLEMS?

The Alternate Heating Systems
B Series
Waste Oil Heater/Boiler
is the most efficient
waste oil heater/boiler on the market!!!

Our Premium 
Waste Oil Heater/Boiler

 

Unique Characteristics of Burning Used Oil

  • Reduced airflow in the waste oil burner can cause incomplete combustion
  • Accumulation of ash produces adverse effects:
  • Reduced heat transfer (U.S. Bureau of Mines).  Research done by the U.S. Bureau of Mines has determined that 1/32-inch of soot coating causes 9.5% loss of burner efficiency.  The following table shows how soot thickness affects burner efficiency
Buildup of Soot in InchesLoss of Efficiency
1/329.5%
1/1626%
1/845%
3/1669%
  • For the following are reasons conventional burners/boilers are not appropriate for burning waste oil:
  1. Improper heat exchanger design
  2. Cannot provide constant airflow volume
  3. Combustion chamber is too small
  4. No refractory lining of combustion chamber or flame target
  5. Poor accessibility for routine cleaning
  • The design of our waste oil heater/boiler addresses all of the problems:
  1. Heat exchanger designed to prevent ash buildup and achieve high transfer efficiency
  2. Large access door provides easy access for maintenance and cleaning
  3. Refractory lined extra large combustion chamber produces high temperature combustion zone
  4. Water tube design for efficiency, improved draft and minimal floor area used with its vertical design

Common Features of Our Waste Oil Heaters/Boilers

Boilers and storage tanks can be custom tailored for your special applications
 Whether for recycling used oil or burning fuel oil (or both), we can size a cost-effective system for you.
Double savings means fast payback
 Heat your facility and generate hot water without cost while eliminating the liability and expense of contract off-site disposal.
EPA approved for recycling used oil
 On-site recycling is the preferred method of avoiding liability and reusing energy to enhance your bottom line.

B Series Waste Oil Heater/Boiler

Waste Oil Heater/Boiler - B Series

The B Series waste oil heater/boiler design is tried and true.  The design has been in operation for over 18 years with a spotless record.  Even after 18 years, our B Series design is still the most state-of-the-art waste oil heater/boiler design on the market.

The following is what makes the B Series design different from our competitors:

  • An Airflow-inducing Fan causes the ash to be pulled through the boiler at high speeds keeping it from depositing on the burner wall.  It also allows adjustment of the airflow according to the desired BTU.
  • The Swirl Chamber is a high pressure area in the burner that allows hot exhaust to reside for a long period of time.  Coupled with a swirling motion, which gives the burner the ability to drop the temperature of the exhaust from 1,800 degrees to as low as 350 degrees (see below) before it is allowed to exit the burner, THE SWIRL CHAMBER IS OUR KEY TO HIGH EFFICIENCY COMBUSTION OF WASTE OIL .
  • The Cyclone Ash Collection System does the major part of the self-cleaning action of our waste oil burner - the rapidly moving ash acts to scour the walls of the inside of the burner preventing buildup and providing a self-cleaning action.  The cyclone funnels the ash into a pail for easy disposal.
  • A Secondary Air Inlet allows oxygen to enter the burn target for secondary combustion - any un-combusted waste oil remaining in the flue gases is provided another opportunity to be completely combusted.

Stack Temperature

The stack temperature is an indicator of how completely the waste oil is being combusted.  The Alternate Heating Systems Inc. B Series operates with one of the coolest stack temperatures of any waste oil heater/boiler on the market (we believe that it is actually the coolest).  Because of the nature of the fuel, the stack temperature will vary.  The low stack temperatures of our boilers are almost unheard of on the market.

Using Fly Ash to Self-Clean the Swirl Chamber

The combustion of the fuel is so thorough that very little fly ash is produced.  But even the fly ash that is produced is put to good use - the system is designed so that the fly ash scours the inside of the swirl chamber, preventing the buildup of creosote that can dramatically lower combustion efficiency.  After scouring the swirl chamber, the little fly ash that remains from the combustion process is deposited in an ash pan that can be easily removed.

B Series Waste Oil Heater/Boiler Specifications*
Test Standards: Etlm 83-1; U.L. 296 & U.L. 726
Approved Fuels: #2 fuel oil, Used Crankcase Oil up to S.A.E. 50 WT, Used Automatic Trans. Fluid
MODEL:   B175B300B500B500MB1000
Net BTUH175,000300,000500,000705,000990,000
Gross BTUH200,000345,000575,000850,000990,000
Heating surface, fireside (sq ft)3361102102220
Furnace Volume (cubic ft)47131326
Minimum Relief Valve Capacity462,000854,0001,428,0001,428,0003,080,000
Firing Rate - U.S. gal/hr1.462.54.06.08.0
Water Volume (gals)100185245245340
Minimum Compressed Air Required10 CFM @ 30 PSI for all models
ID Fan Motor HP1/33/411-1/22
Electrical Rating (other options are available)110 V, 60 Hz, 15 Amp110 V, 60 Hz, 20 Amp220 V, 60 Hz, 15 Amp220 V, 60 Hz, 20 Amp220 V, 60 Hz, 25 Amp
Electrical Circuit Protector Max.15 AmpSingle Phase 20 AmpDouble Phase 20 AmpDouble Phase 25 AmpDouble Phase 30 Amp
Flue Dimensions6"6"8"8"8"
Length43"60"72"72"96"
Width26"32"34"34"42"
Width with Cyclone40"51"58"58"70"
Height38"46"54"54"71"
Shipping weight (lbs)1,1001,7002,6002,7005,000
Minimum Clearance to Combustibles (all models):
Above:  12"                       Sides:  24"                       Rear:  36"
Front (servicing):  36"                       Chimney Connector:  18"
Minimum Clearance to Service (all models):
Above:  24"                       Sides:  24"                       Rear:  36"
Front (servicing):  72"                       Chimney Connector:  18"

*Specifications and design subject to change without notice.
All specifications are approximate.


WOOD GASIFICATION BOILERS

Airflow Diagram

Multiple Sizes of Wood Gasification Boilers

Model:

E100

E140

E180

E200

E250

BTU/H (Max.) Wood

100,000

140,000

150,000

185,000

230,000

Oil (optional) **

80,000

130,000

160,000

160,000

230,000

Heating Surface

30 ft2

39 ft2

46 ft2

55 ft2

70 ft2

Water Capacity

60 Gal

80 Gal

80 Gal

95 Gal

140 Gal

Fire Box Capacity

6.5 ft3

10 ft3.

14 ft3

18 ft3

22 ft3

Max. Log Length

26"

30"

30"

38"

46"

Door Opening

14" x14"

14" x14"

14" x14"

14" x14"

14" x14"

Height

58"

64"

66"

66"

74"

Width

26"

26"

31"

31"

31"

Depth

44"

48"

48"

56"

66"

Flue Size

6"

6"

6"

8"

8"

Weight (lbs)

1,400

1,650

2,100

2,400

3,000

Domestic Coil Gal/min (Optional)

5

5

5

5

5

Rec. Sizing: for 8 - 12 hour burn cycle (BTU/hr)

70,000

100,000

140,000

175,000

220,000

 

Model:

E500

E1000

BTU/H (Max.) Wood

500,000

1,000,000

Net Steam Rating (BTU/H)

376,000

752,000

Heating Surface

116 ft2

192 ft2

Water Capacity

210 Gal

435 Gal

Gas/Oil Chamber (water capacity)

16 Gal

50 Gal

Height

90"

102"

Width

34"

48"

Depth

72"

78"

Flue Size

8"

12"

Weight (w/o gas/oil - lbs)

4,500

9000

ID Fan

.75 HP

2.0 HP

Minimum Boiler Room (w/o Gas/Oil)

12'x15'

16'x16'

Minimum Boiler Room (with Gas/Oil)

14'x15'

16'x18'

Load Door

18"x18"

18"x18"

* Specifications and design subject to change without notice.
All specifications shown are approximate.


The Alternate Heating Systems Water Wall

Each Alternate Heating Systems boiler, heater and furnace is designed so that every piece of steel is in contact with the water in the system that is used to transfer heat to your radiant floor heat system, radiator, baseboard hot water, or heat exchanger.  This design ensures the most rapid and efficient heat transfer from the firebox into the water.  Efficiency is increased compared to other boilers that do not have this feature by allowing less heat to escape from the boiler surfaces before it is captured in the water.

ASME Certification

The American Society of Mechanical Engineers certification is available on any of our boiler lines for an additional charge.  This certification assures that the pressure vessel has been designed and constructed in accordance with the ASME Code.  This certification is required for all commercial installations.  The certification is also required for some residential installations depending upon local codes - it is up to the homeowner to determine the need for an ASME certification on any boiler purchased.

10 Year Limited Warranty

 
© 2010 Waste Oil Furnace Distributing, LLC